COMMERCIAL TEMPERATURE RANGE
IDT7290820 5V TIME SLOT INTERCHANGE
DIGITAL SWITCH 2,048 x 2,048
DS
5713 drw16
ADDRESS
t
CSS
t
DSH
t
ASW
t
CSH
t
DDR
t
ADS
t
ADH
AD0-AD7
D8-D15
WR
CS
DTA
DATA
ADDRESS
DATA
t
RWS
t
DWS
t
SW
t
DHW
t
AKD
AD0-AD7
D8-D15
RD
R/W
AS
t
RWH
t
DHR
t
AKH
AC ELECTRICAL CHARACTERISTICS - MULTIPLEXED BUS TIMING (MOTOROLA)
Figure 13. Multiplexed Bus Timing (Motorola Mode)
Symbol Parameter Min. Typ. Max. Units Test Conditions
tASW ALE Pulse Width 80 ns
tADS Address Setup from AS falling 10 ns
tADH Address Hold from AS falling 10 ns
tDDR Data Setup from DTA LOW on Read 10 ns CL = 150pF
tCSH CS Hold after DS falling 0 ns
tCSS CS Setup from DS rising 0 ns
tDHW Data Hold after Write 10 ns
tDWS Data Setup from DS – Write (Fast Write) 25 ns
tSWD Valid Data Delay on Write (Slow Write) 122 ns
tRWS R/W Setup from DS Rising 60 ns
tRWH R/W Hold from DS Rising 10 ns
tDHR
(1)
Data Hold after Read 10 50 75 ns CL = 150pF, RL = 1K
tDSH DS Delay after AS falling 10 ns
tAKD Acknowledgment Delay:
Reading/Writing Registers 55/60 ns CL = 150pF
Reading/Writing Memory @ 2.048 Mb/s 760/780 ns CL = 150pF
@ 4.096 Mb/s 400/420 ns CL = 150pF
@ 8.192 Mb/s 220/240 ns CL = 150pF
tAKH
(1)
Acknowledgment Hold Time 45 80 n s CL = 150pF, RL = 1K